top of page

 IAM 

Ionisationsmodul

The use of ionization in cleanrooms is an absolute necessity in areas where special agents cannot be used to reduce the effects of static electricity on electrostatically sensitive products.

 

It should also be noted that the ionizers are excellent for removing different kinds of pollution, which are known to attract dust. In addition, our ionizers meet the requirements of modern production facilities, including rooms of high cleanliness class.

IAM.png

Structure

An IAM ionization module contains axial fans and high-voltage electrodes for electrostatic neutralization of the air flow. The fan unit draws in the air and conveys it further with the help of the fans, past the ionization electrodes.

These electrodes must always be placed last, so that the outgoing air stream flows around the electrodes and thus transports the positive and negative ions into the room.

 

A light grid closes off the ionization modules at the bottom and thus prevents any unauthorized access to the high-voltage electrodes.

The control system and the high-voltage supply are installed in the upper part of the ionization modules.

Operation

The air volume flow with optional upstream filter system builds up overpressure in an enclosed space.

builds up overpressure. An effective range is achieved in the entire area, particles are reduced to cleanroom quality by the filter system. 

Contact protection

The IAM ionization modules are closed off with a protective grid. This grid serves as a safety protection to prevent contact with the electrodes (of high voltage).

The contact protection consists of a protective grid that is permanently installed in the construction and is made of a non-conductive plastic (contact protection in accordance with the applicable safety regulations).

The protective grid can be removed for changing the discharge electrodes.

Technics

Case structure

Aluminum sheet case

Aluminum, anodized

​

Air volume flow

Axial fan, silent running

Rectifier for the air volume flow

for uniform distribution of the air volume flow

​

Speed controller

optional

Manual adjustment of the grade of ionization

Rotary control without lamp on switch module

 

Control unit

MSR module axial fan, air ionization and high voltage;

incl. switch module and main fuse;

Switch module integrated in the ionization module

Connection cable for electrical connection to 230 volts

Length, standard: 3.0 m, designed as desired

 

Other

Plastic protection and flow grids

 

Type

IAM

For the exact designation of your ionization module, see

the label on the side of your module. The size can be

individually designed according to customer requirements

 

Type / Length (mm) / Width (mm) / Height (mm) / Air flow ( m³/h )

IAM 1 / 380 / 160 / 86 /120

 

IAM 2 / 514 / 160 / 86 / 220

 

IAM 3 / 788 / 160 / 86 / 330

 

IAM 4 / 1020 / 160 / 86 / 440

 

IAM 5 / 1252 / 160 / 86 / 550

 

IAM 6 / 1482 / 160 / 86 / 660

 

Fan type

Axial fan

 

Number of fans

depending on the version of the ionization module

Installation and safety instructions for the axial fans can be found in section 7 of this technical documentation.

 

Ionization

Type: DC voltage

Electrodes: positive and negative: 1

​

Electrical connection

230 AC, max. 2 A
 

Frequency

50 - 60 Hz